What is load sharing in generator?
Table of Contents
Load sharing is defined as the proportional division of the kW and kVAR total load between multiple generator sets in a paralleled system. Load sharing is essential to avoid overloading and stability problems on the systems’ generator sets.
Can you parallel different size Generac generators?

Paralleling offers more flexibility and redundancy and can be used to allow two or more smaller generators to perform like a single larger one. The generators need to be synchronized. To do that, the control systems of the generators need to talk to each other.
How do you sync two generators together?
For two generators to be synchronized they must have equal number of phase; same phase angle, same voltage, frequency and identical voltage sine curve ( waveform ). This means the RYB connection point of bus bar; should be connected to RYB terminals of incoming generator and not RBY.
What is synchronizing and load sharing?
A load sharing system will continuously adjust the engine speed settings to avoid fluctuations in the average power that is generated. The gen-sets are bundled as if they were one by synchronizing the electrical output torque. This way they will behave as if they are mechanically tied together.

Can 2 generators be connected together?
Although individual portable generators can only put out so much power, it’s possible to combine two of them to get double the wattage. This is called paralleling generators and is an easy workaround that will let you power larger loads like RV air conditioners with smaller units.
Can 2 different generators be connected together?
What controls the load on a generator?
An electronic load controller or governor is a device which is designed to ensure that the electrical load on a generator remains constant.
How do two ship AC generators share a load?
Two ship ac generators sharing load With two ac generators sharing load in parallel, their terminal voltages and frequencies both must be equal, and the frequency droop lines of two ac generators determine their share of the total load. The frequencies of Generator 1 and Generator 2 at their own load
What happens when two AC generators share load in parallel?
With two ac generators sharing load in parallel, their terminal voltages and frequencies both must be equal, and the frequency droop lines of two ac generators determine their share of the total load. The frequencies of Generator 1 and Generator 2 at their own load
How to do frequency sharing on ship parallel connection generators?
By parallel connection, we impose on the bus that f1 = f2 = fbus, that is, Frequency sharing on ship parallel connection generators Solving Equations and simultaneously for P1 and P2 (with all other parameters known), we get the load shared by Generators 1 and 2. Load sharing on two ship generators
What happens when you add a powerful generator to a generator?
The powerful generator will try to pull ahead (phase advancement) of the lower generator and will be required to provide more power. Thus automatic sharing of load, tho not at exactly 50%. Now, for controlling that frequency. Show activity on this post.